影(ying)響蓄電(dian)池(chi)壽(shou)命的因素 教(jiao)你(ni)正確使(shi)用和維護蓄電(dian)池(chi)
影響蓄電池壽命的因素
1、影響蓄電池內阻的因素主要有:
1)蓄(xu)(xu)電(dian)池(chi)(chi)使用的(de)時(shi)間:隨著(zhu)使用時(shi)間的(de)增加(jia),使電(dian)解(jie)液失水、極板與連(lian)接條(tiao)的(de)腐(fu)蝕、極板的(de)硫酸化、極板變(bian)形及活性(xing)物質的(de)脫落等因(yin)素(su),造成蓄(xu)(xu)電(dian)池(chi)(chi)容量減小(xiao),蓄(xu)(xu)電(dian)池(chi)(chi)內阻變(bian)大(da)。
2)蓄電(dian)(dian)池的電(dian)(dian)荷量:由(you)于注入蓄電(dian)(dian)池的電(dian)(dian)解液深度(du)、電(dian)(dian)極(ji)表(biao)面(mian)反應(ying)物(wu)質的厚度(du)、電(dian)(dian)極(ji)表(biao)面(mian)的孔(kong)隙率等不同,而使蓄電(dian)(dian)池的內阻相(xiang)差(cha)較大,從而電(dian)(dian)荷量也相(xiang)差(cha)較大。
3)溫(wen)(wen)度(du):環境(jing)溫(wen)(wen)度(du)的變(bian)化,例(li)如上升,這時反應物質的擴散(san)加(jia)(jia)快、電(dian)荷(he)傳(chuan)遞、電(dian)極動(dong)力(li)學(xue)過程和物質轉移更容(rong)易進行(xing),因而(er)蓄電(dian)池(chi)內(nei)阻減小。反之(zhi),就會增加(jia)(jia)。
4)蓄(xu)(xu)(xu)電(dian)池(chi)(chi)的(de)型(xing)號:不同(tong)生(sheng)產廠、不同(tong)種類、不同(tong)型(xing)號的(de)蓄(xu)(xu)(xu)電(dian)池(chi)(chi),由(you)于電(dian)極、電(dian)解液、隔膜的(de)材料配方不同(tong),電(dian)池(chi)(chi)的(de)結構不同(tong)、裝配工藝不同(tong)而使蓄(xu)(xu)(xu)電(dian)池(chi)(chi)內阻產生(sheng)差異。
5)測(ce)(ce)量信號頻率:目(mu)前(qian)許多蓄(xu)(xu)電池(chi)內阻(zu)測(ce)(ce)量,實(shi)際上測(ce)(ce)的(de)是蓄(xu)(xu)電池(chi)的(de)阻(zu)抗,內中(zhong)包(bao)括了容(rong)抗,而容(rong)抗大小和(he)測(ce)(ce)量信號頻率有(you)關,使(shi)蓄(xu)(xu)電池(chi)內阻(zu)測(ce)(ce)量結(jie)果(guo)(guo)不(bu)具有(you)客(ke)觀(guan)性(xing)(xing)。要具有(you)客(ke)觀(guan)性(xing)(xing),應(ying)根(gen)據測(ce)(ce)量信號電流和(he)電壓的(de)相位關系,用(yong)解(jie)析的(de)方法去除蓄(xu)(xu)電池(chi)電容(rong)對測(ce)(ce)量結(jie)果(guo)(guo)的(de)影響(xiang),使(shi)測(ce)(ce)量率結(jie)果(guo)(guo)與(yu)信號測(ce)(ce)量頻率無關,即在任何測(ce)(ce)量信號頻率下,內阻(zu)測(ce)(ce)量結(jie)果(guo)(guo)具有(you)唯(wei)一性(xing)(xing)。
6)測(ce)量(liang)(liang)(liang)(liang)時間和測(ce)量(liang)(liang)(liang)(liang)電流(liu)(liu)大小(xiao):在(zai)采用較大測(ce)量(liang)(liang)(liang)(liang)電流(liu)(liu)的(de)(de)情(qing)況下(xia),在(zai)施加測(ce)量(liang)(liang)(liang)(liang)信(xin)號(hao)和關閉測(ce)量(liang)(liang)(liang)(liang)信(xin)號(hao)的(de)(de)瞬間,由于極化的(de)(de)建立和穩定是個變(bian)化過程,不(bu)同的(de)(de)測(ce)量(liang)(liang)(liang)(liang)電流(liu)(liu),不(bu)同的(de)(de)測(ce)量(liang)(liang)(liang)(liang)時間,極化是不(bu)同的(de)(de),使蓄電池內阻(zu)(zu)測(ce)量(liang)(liang)(liang)(liang)結果不(bu)具(ju)有客觀性。要(yao)具(ju)有客觀性,應(ying)盡(jin)量(liang)(liang)(liang)(liang)用較小(xiao)的(de)(de)信(xin)號(hao)電流(liu)(liu)進行內阻(zu)(zu)測(ce)量(liang)(liang)(liang)(liang),根據(ju)實(shi)驗,測(ce)量(liang)(liang)(liang)(liang)電流(liu)(liu)小(xiao)于或(huo)等于0.05C10,(其中C10為10小(xiao)時放電率下(xia)蓄電池的(de)(de)容量(liang)(liang)(liang)(liang)。)
2、過度充電的影響
長(chang)期過(guo)充電(dian)狀態下,正(zheng)極(ji)因(yin)析氧反應,水(shui)被消耗,h+增加,從而(er)導致正(zheng)極(ji)附近酸度增加,板(ban)柵(zha)腐(fu)蝕加速,使(shi)板(ban)柵(zha)變薄加速電(dian)池的腐(fu)蝕,使(shi)電(dian)池容量(liang)降低;同時(shi)因(yin)水(shui)損耗加劇,將使(shi)蓄(xu)電(dian)池有干涸的危險,從而(er)影響(xiang)蓄(xu)電(dian)池壽(shou)命。
3、過度放電的影響
蓄(xu)(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)過(guo)度放(fang)電(dian)(dian)(dian)(dian)主要(yao)發(fa)生在交流電(dian)(dian)(dian)(dian)源停電(dian)(dian)(dian)(dian)后,蓄(xu)(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)長時間為負(fu)載供(gong)電(dian)(dian)(dian)(dian)。當蓄(xu)(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)被(bei)(bei)過(guo)度放(fang)電(dian)(dian)(dian)(dian)到(dao)其電(dian)(dian)(dian)(dian)壓過(guo)低甚至為零(ling)時,會(hui)導致電(dian)(dian)(dian)(dian)池(chi)(chi)內部有大(da)量的(de)(de)(de)(de)硫(liu)酸鉛(qian)被(bei)(bei)吸附(fu)到(dao)蓄(xu)(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)的(de)(de)(de)(de)陰(yin)(yin)極(ji)表(biao)面(mian),在電(dian)(dian)(dian)(dian)池(chi)(chi)的(de)(de)(de)(de)陰(yin)(yin)極(ji)造成“硫(liu)酸鹽化”。硫(liu)酸鉛(qian)是一(yi)種絕緣體,它的(de)(de)(de)(de)形成必將(jiang)對(dui)蓄(xu)(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)的(de)(de)(de)(de)充(chong)、放(fang)電(dian)(dian)(dian)(dian)性能產生很大(da)的(de)(de)(de)(de)負(fu)面(mian)影響,因此在陰(yin)(yin)極(ji)上形成的(de)(de)(de)(de)硫(liu)酸鹽越(yue)多,蓄(xu)(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)的(de)(de)(de)(de)內阻越(yue)大(da),電(dian)(dian)(dian)(dian)池(chi)(chi)的(de)(de)(de)(de)充(chong)、放(fang)電(dian)(dian)(dian)(dian)性能就越(yue)差,蓄(xu)(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)的(de)(de)(de)(de)使(shi)用壽命就越(yue)短(duan)。
蓄電池使用和維護需遵循的原則
1、密(mi)封電池(chi)可允許的運行(xing)范圍為15度-50度,但5度-35度之內使用可延長電池壽命。在零下15度以下電池化(hua)(hua)學成(cheng)分將發生(sheng)變化(hua)(hua)而(er)不能充電。在(zai)20度到25度范圍內(nei)使用(yong)將(jiang)獲得(de)最高壽命(ming).電池在(zai)低溫(wen)運行將獲得長(chang)壽(shou)命(ming)但較低容量,在(zai)高溫(wen)運行將獲得較高容量但短壽(shou)命(ming)。
2、電池壽(shou)命(ming)和溫(wen)度的關系可參考如下(xia)規則,溫(wen)度超過攝氏25度(du)后,每高8.3度電池壽命將減一(yi)半(ban)。
3、免維護電池的(de)設計浮充電壓為2.3V/節。12V的電池(chi)為13.8V。在(zai)120節電(dian)池(chi)串聯的情況(kuang)下,溫度(du)高于攝氏(shi)25度(du)(du)后,溫度(du)(du)每升高(gao)一(yi)度(du)(du)浮充電壓(ya)應下調(diao)3MV。同樣(yang)溫度(du)每升高一(yi)度(du)為避(bi)免充電不足(zu)電壓應(ying)上調3MV。放電終止電壓在滿負荷(<30分鐘)情況下為(wei)1.67V每節(jie)。在低放電(dian)率情況下(小(xiao)電(dian)流長時間放電(dian))要升高至1.7V-1.8V每(mei)節。
4、放電結束后電池若在(zai)72小時內沒有再次充(chong)(chong)電(dian)。硫酸鹽將附著在極板上絕緣充(chong)(chong)電(dian),而(er)損(sun)壞電(dian)池。
5、電(dian)(dian)池(chi)在浮(fu)充或均充時,電(dian)(dian)池(chi)內部產生(sheng)的氣體在負極板(ban)電(dian)(dian)解成水,從(cong)而保持電(dian)(dian)池(chi)的容量且(qie)不必外加水。但(dan)電(dian)(dian)池(chi)極板(ban)的腐蝕(shi)將減低電(dian)(dian)池(chi)容量。
6、電池隔板壽命在環境溫(wen)度為30-40度時(shi)僅為5-6個月。長時間存放的(de)電池每6個月必須(xu)充電(dian)(dian)一次(ci)。電(dian)(dian)池(chi)必須(xu)存放在(zai)干燥涼爽的環境。在(zai)20度的(de)環境下免維護電(dian)池的(de)自(zi)放電(dian)率(lv)為(wei)3-4%每個月,并隨溫度變化(hua)。
7、免維護電池(chi)都配有安(an)全(quan)閥(fa),當電池(chi)內(nei)部氣壓升高到一定程度(du)時(shi)安(an)全(quan)閥(fa)可自(zi)動(dong)排除過(guo)剩氣體,在內(nei)部氣壓恢復時(shi)安(an)全(quan)閥(fa)會自(zi)動(dong)恢復。
8、電(dian)池(chi)的周期壽命(充放電(dian)次(ci)數壽命)取決(jue)于放電(dian)率(lv),放電(dian)深度,和恢(hui)復性(xing)充電(dian)的方式,其(qi)中(zhong)最重要的因素是放電(dian)深度。在放電(dian)率(lv)和時(shi)間一定(ding)時(shi),放電(dian)深度越淺,電(dian)池(chi)周期壽命越長(chang)。免維護電(dian)池(chi)在25度(du)100%深放電情況下周期壽命(ming)約(yue)為200次(ci)。
9、電池在到(dao)達壽命時表現為容量衰減,內部短路,外殼(ke)變形,極板腐蝕,開路電壓降(jiang)低。
10、電池壽(shou)命結束為(wei)容(rong)量不(bu)足(zu)標稱容(rong)量AH的80%。標稱容量和實(shi)際(ji)后備時間非線性關系,容量減低20%相應后(hou)備時間會減低很多。一些UPS廠家定義電池的壽命終止為容量(liang)降至標稱容量(liang)的50-60%。
11、絕對禁止不同容量和不同廠家的電池混用,否則會(hui)降低電池壽命(ming)。
12、若兩組電(dian)(dian)池(chi)并(bing)聯使用(yong),應保(bao)證電(dian)(dian)池(chi)連線,匯流排(pai)阻抗相同。
13、免維護(hu)電池意(yi)味著可以不用加液(ye),但定(ding)期檢查外殼有無裂縫(feng),電解液(ye)有無滲漏等仍為必要(yao)的。