一、多功能電力儀表接線方法
多(duo)功(gong)(gong)(gong)(gong)能電(dian)(dian)(dian)(dian)(dian)力(li)(li)儀(yi)表是專為配電(dian)(dian)(dian)(dian)(dian)系統、工礦(kuang)企業(ye)、公共樓宇的(de)(de)電(dian)(dian)(dian)(dian)(dian)力(li)(li)監(jian)控(kong)系統而(er)設計的(de)(de)電(dian)(dian)(dian)(dian)(dian)力(li)(li)設備,它可(ke)以測量三相交流電(dian)(dian)(dian)(dian)(dian)路(lu)上的(de)(de)常用電(dian)(dian)(dian)(dian)(dian)力(li)(li)參數,如三相相電(dian)(dian)(dian)(dian)(dian)壓、三相線電(dian)(dian)(dian)(dian)(dian)壓、三相電(dian)(dian)(dian)(dian)(dian)流、有(you)功(gong)(gong)(gong)(gong)、無(wu)功(gong)(gong)(gong)(gong)、視在功(gong)(gong)(gong)(gong)率、功(gong)(gong)(gong)(gong)率因(yin)數、頻率、四(si)象限電(dian)(dian)(dian)(dian)(dian)能等,使用多(duo)功(gong)(gong)(gong)(gong)能電(dian)(dian)(dian)(dian)(dian)力(li)(li)儀(yi)表時(shi),需要先將其安裝好并接線,那么多(duo)功(gong)(gong)(gong)(gong)能電(dian)(dian)(dian)(dian)(dian)力(li)(li)儀(yi)表怎么接線呢?
一般來說,多功能(neng)電力儀表的接(jie)(jie)線(xian)方法(fa)和接(jie)(jie)線(xian)圖在使用說明書上都有,按照接(jie)(jie)線(xian)圖將各端子連接(jie)(jie)起來即可,常(chang)見的接(jie)(jie)線(xian)方法(fa)主要有三種:
1、直接接線法
(1)首先確認電纜線的電壓級(ji)別和電流大小。將電纜分別連接(jie)到儀表的L1、L2、L3、N和PE接(jie)線端。
(2)將電纜線(xian)連接到電源端,確認線(xian)序正確。
(3)確(que)認接線端是否牢固,如有(you)松動需要(yao)重新插拔(ba)和連接。
(4)開啟電(dian)源(yuan),檢測儀表(biao)的電(dian)壓(ya)、電(dian)流、功(gong)率等參(can)數是(shi)否(fou)符合實際值。
(5)如(ru)必要,調整儀表的(de)校準參數,確保讀(du)數準確。
2、三元組接線法
(1)將三根電纜(lan)(lan)線(A、B、C)依(yi)次(ci)連接(jie)(jie)到(dao)儀表(biao)的(de)L1、L2、L3接(jie)(jie)線端,將剩余兩根電纜(lan)(lan)線(N、PE)連接(jie)(jie)到(dao)儀表(biao)的(de)N和(he)PE接(jie)(jie)線端。
(2)確認連接結果(guo)正確。
(3)開啟電(dian)源,檢測儀表的電(dian)壓、電(dian)流、功(gong)率等參數(shu)是(shi)否符合(he)實際值。
(4)如(ru)必要,調整儀(yi)表的校準參數,確保讀數準確。
3、變壓器接線法
(1)將三根(gen)電(dian)(dian)纜(lan)線(A、B、C)分別接(jie)到(dao)變壓器(qi)的高壓端(duan),將剩余兩根(gen)電(dian)(dian)纜(lan)線(N、PE)接(jie)到(dao)變壓器(qi)的中性點和接(jie)地端(duan)。
(2)將變壓器的低壓端(duan)(duan)連(lian)接(jie)到(dao)儀(yi)表的L1、L2、L3接(jie)線(xian)(xian)端(duan)(duan),將剩余兩根電纜(lan)線(xian)(xian)(N、PE)連(lian)接(jie)到(dao)儀(yi)表的N和PE接(jie)線(xian)(xian)端(duan)(duan)。
(3)確認連接結果正確。
(4)開啟電源,檢測儀表的電壓、電流、功率等參數是否(fou)符合實際值。
(5)如(ru)必要,調整儀表的校準(zhun)參數,確(que)保讀數準(zhun)確(que)。
二、三相多功能電力儀表接線注意事項有哪些
三相多功能電力儀表的(de)接(jie)線方法(fa)多(duo)種多(duo)樣,可(ke)以根據實(shi)際(ji)情況(kuang)選擇合適的(de)接(jie)線方法(fa),正確的(de)接(jie)線方式不僅可(ke)以保(bao)證儀表的(de)正常使(shi)用,還能有效防止安全事(shi)(shi)故的(de)發(fa)生,在(zai)進(jin)行接(jie)線時,還要注意(yi)以下幾個(ge)事(shi)(shi)項:
1、接(jie)線(xian)前需確(que)(que)認(ren)電纜線(xian)的電壓(ya)級別和(he)電流大小,接(jie)線(xian)時應保(bao)證線(xian)序(xu)正確(que)(que)。
2、接線端應牢固(gu),如有松動(dong)需(xu)要重新插拔和連接。
3、開(kai)啟電源前應確(que)認所(suo)有接(jie)線是(shi)否正確(que),避(bi)免短路或漏電。
4、輸(shu)入電壓不要(yao)高于產品(pin)的額定(ding)輸(shu)入電壓(100V到380V),否則(ze)應考慮使(shi)用(yong)(yong)PT,為了方便維(wei)護,建(jian)議使(shi)用(yong)(yong)接(jie)線排(pai)。
5、標準額定輸(shu)入電流為5A或1A,大(da)于5A的(de)情況應使用(yong)外部CT。如果使用(yong)的(de)CT上連(lian)有其他儀表,接(jie)線應采用(yong)串(chuan)聯方式,取出產(chan)品的(de)電流輸(shu)入連(lian)線之(zhi)前(qian),一(yi)定要先斷(duan)開(kai)CT一(yi)次回路或者短接(jie)二次回路,為便于維(wei)護建議(yi)使用(yong)連(lian)線排。
6、要確保輸(shu)入(ru)電壓,電流相(xiang)對應、相(xiang)序一致、方(fang)向一致、否則會(hui)出現功率和電能等(deng)的數值和符合錯誤。
7、現場(chang)的(de)接(jie)線方(fang)式(shi)必須(xu)與(yu)表內設置的(de)接(jie)線方(fang)式(shi)一致,否(fou)則儀表的(de)測(ce)量(liang)數據不正確。