一、如何檢定爐溫測試儀
爐(lu)溫(wen)測(ce)(ce)(ce)(ce)試(shi)儀(yi)(yi)(yi)(yi)(yi)是工業生產中常用(yong)的(de)測(ce)(ce)(ce)(ce)量(liang)設備(bei),可(ke)(ke)以用(yong)于(yu)(yu)測(ce)(ce)(ce)(ce)量(liang)鍋爐(lu)、窯爐(lu)、熱(re)處(chu)理爐(lu)等(deng)設備(bei)的(de)溫(wen)度(du)(du)(du),為保證爐(lu)溫(wen)測(ce)(ce)(ce)(ce)試(shi)儀(yi)(yi)(yi)(yi)(yi)的(de)測(ce)(ce)(ce)(ce)量(liang)精度(du)(du)(du),必須對(dui)其進(jin)(jin)(jin)(jin)(jin)(jin)行(xing)(xing)定(ding)(ding)(ding)(ding)期的(de)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding)和(he)校準(zhun)(zhun):1、爐(lu)溫(wen)測(ce)(ce)(ce)(ce)試(shi)儀(yi)(yi)(yi)(yi)(yi)的(de)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding)方(fang)法:(1)外(wai)觀(guan)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)查(cha)(cha):首先對(dui)爐(lu)溫(wen)測(ce)(ce)(ce)(ce)試(shi)儀(yi)(yi)(yi)(yi)(yi)的(de)外(wai)觀(guan)進(jin)(jin)(jin)(jin)(jin)(jin)行(xing)(xing)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)查(cha)(cha),確保其外(wai)表無破(po)損、變形(xing)等(deng)異常情(qing)況。(2)環(huan)境(jing)適應性(xing)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)查(cha)(cha):將爐(lu)溫(wen)測(ce)(ce)(ce)(ce)試(shi)儀(yi)(yi)(yi)(yi)(yi)置于(yu)(yu)環(huan)境(jing)溫(wen)度(du)(du)(du)為20℃±5℃、相(xiang)對(dui)濕度(du)(du)(du)為不(bu)超過80%的(de)環(huan)境(jing)中,并(bing)保持一定(ding)(ding)(ding)(ding)時(shi)間(jian)后進(jin)(jin)(jin)(jin)(jin)(jin)行(xing)(xing)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)測(ce)(ce)(ce)(ce),確保其儀(yi)(yi)(yi)(yi)(yi)表指針或數字顯示(shi)與(yu)標(biao)(biao)準(zhun)(zhun)溫(wen)度(du)(du)(du)相(xiang)符。(3)基本誤差(cha)(cha)(cha)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding):使用(yong)標(biao)(biao)準(zhun)(zhun)爐(lu)對(dui)爐(lu)溫(wen)測(ce)(ce)(ce)(ce)試(shi)儀(yi)(yi)(yi)(yi)(yi)進(jin)(jin)(jin)(jin)(jin)(jin)行(xing)(xing)基本誤差(cha)(cha)(cha)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding),采用(yong)兩種(zhong)不(bu)同溫(wen)度(du)(du)(du)點進(jin)(jin)(jin)(jin)(jin)(jin)行(xing)(xing)校準(zhun)(zhun),分別(bie)為200℃和(he)500℃。校準(zhun)(zhun)要求(qiu)誤差(cha)(cha)(cha)為±0.5℃。(4)穩定(ding)(ding)(ding)(ding)性(xing)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding):將爐(lu)溫(wen)測(ce)(ce)(ce)(ce)試(shi)儀(yi)(yi)(yi)(yi)(yi)置于(yu)(yu)標(biao)(biao)準(zhun)(zhun)溫(wen)度(du)(du)(du)下(xia),保持一定(ding)(ding)(ding)(ding)時(shi)間(jian)后進(jin)(jin)(jin)(jin)(jin)(jin)行(xing)(xing)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)測(ce)(ce)(ce)(ce),與(yu)第3步(bu)的(de)測(ce)(ce)(ce)(ce)量(liang)值進(jin)(jin)(jin)(jin)(jin)(jin)行(xing)(xing)比對(dui),誤差(cha)(cha)(cha)要求(qiu)小于(yu)(yu)±0.5℃。(5)重復(fu)性(xing)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding):在(zai)相(xiang)同條(tiao)件下(xia)進(jin)(jin)(jin)(jin)(jin)(jin)行(xing)(xing)多次(ci)測(ce)(ce)(ce)(ce)定(ding)(ding)(ding)(ding),并(bing)對(dui)不(bu)同測(ce)(ce)(ce)(ce)量(liang)結果進(jin)(jin)(jin)(jin)(jin)(jin)行(xing)(xing)比對(dui),誤差(cha)(cha)(cha)要求(qiu)小于(yu)(yu)±0.5℃。2、爐(lu)溫(wen)測(ce)(ce)(ce)(ce)試(shi)儀(yi)(yi)(yi)(yi)(yi)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding)要求(qiu):(1)儀(yi)(yi)(yi)(yi)(yi)器檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding)周期為1年。(2)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding)時(shi)應嚴(yan)格(ge)按(an)照檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding)方(fang)法進(jin)(jin)(jin)(jin)(jin)(jin)行(xing)(xing)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding)和(he)校準(zhun)(zhun),確保校準(zhun)(zhun)的(de)精度(du)(du)(du)和(he)可(ke)(ke)靠性(xing)。(3)對(dui)于(yu)(yu)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding)不(bu)合格(ge)的(de)爐(lu)溫(wen)測(ce)(ce)(ce)(ce)試(shi)儀(yi)(yi)(yi)(yi)(yi),應及時(shi)進(jin)(jin)(jin)(jin)(jin)(jin)行(xing)(xing)修理、調整或更換。(4)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding)結果應記錄(lu)在(zai)檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding)記錄(lu)表中,檢(jian)(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)(ding)記錄(lu)表應保存至少10年。
二、爐溫測試儀怎么刪除記錄
爐(lu)溫(wen)(wen)(wen)(wen)測(ce)(ce)試(shi)(shi)儀(yi)(yi)是工(gong)業生產中常(chang)用的(de)(de)一種溫(wen)(wen)(wen)(wen)度測(ce)(ce)試(shi)(shi)設備,它可(ke)以(yi)測(ce)(ce)量高(gao)溫(wen)(wen)(wen)(wen)環(huan)境下的(de)(de)溫(wen)(wen)(wen)(wen)度變化,并(bing)(bing)且(qie)可(ke)以(yi)記錄(lu)溫(wen)(wen)(wen)(wen)度數據(ju)(ju),有的(de)(de)爐(lu)溫(wen)(wen)(wen)(wen)測(ce)(ce)試(shi)(shi)儀(yi)(yi)會自(zi)動(dong)(dong)覆蓋老(lao)的(de)(de)數據(ju)(ju)記錄(lu),有的(de)(de)則需要(yao)手動(dong)(dong)刪除,一般(ban)爐(lu)溫(wen)(wen)(wen)(wen)測(ce)(ce)試(shi)(shi)儀(yi)(yi)刪除記錄(lu)方法步驟是:1、打開爐(lu)溫(wen)(wen)(wen)(wen)測(ce)(ce)試(shi)(shi)儀(yi)(yi),并(bing)(bing)連接(jie)到電(dian)(dian)腦(nao)。2、在(zai)電(dian)(dian)腦(nao)上安裝爐(lu)溫(wen)(wen)(wen)(wen)測(ce)(ce)試(shi)(shi)儀(yi)(yi)的(de)(de)驅動(dong)(dong)程序,確(que)保電(dian)(dian)腦(nao)能夠識(shi)別爐(lu)溫(wen)(wen)(wen)(wen)測(ce)(ce)試(shi)(shi)儀(yi)(yi)。3、打開爐(lu)溫(wen)(wen)(wen)(wen)測(ce)(ce)試(shi)(shi)儀(yi)(yi)軟件(jian),在(zai)軟件(jian)中找到爐(lu)溫(wen)(wen)(wen)(wen)數據(ju)(ju)的(de)(de)存儲位(wei)置。4、選(xuan)中需要(yao)清理的(de)(de)數據(ju)(ju)文件(jian),右鍵點擊文件(jian),并(bing)(bing)選(xuan)擇“刪除”。5、在(zai)彈出對話框中確(que)認刪除操作(zuo)。完(wan)成后,爐(lu)溫(wen)(wen)(wen)(wen)測(ce)(ce)試(shi)(shi)儀(yi)(yi)里的(de)(de)數據(ju)(ju)記錄(lu)就被(bei)刪除干凈了。
三、爐溫測試儀價格多少錢一臺
一般來說,爐溫測試儀的價格與它的生產廠家、性能參數、測量范圍、尺寸大小等多方面因素有關,市場價有高有低,從兩三千元一臺到幾萬元一臺都有。選擇爐溫測試儀時,應綜合考慮多個方面,選擇適合生產需要的爐溫跟蹤系統,主要考慮的因素包括產品制程的需要、參數、物理尺寸、電池、無鉛制程、穩定性、精確性等方面,如果您有采購的需要,建議先來了解一下爐溫測試儀十大品牌。
四、爐溫測試儀使用教程
1、將(jiang)(jiang)(jiang)爐(lu)溫(wen)(wen)(wen)測(ce)試(shi)儀(yi)(yi)同(tong)(tong)外置(zhi)PCB連線(xian)(xian)按(an)(an)插頭編(bian)號(hao)連接(jie)好(hao),同(tong)(tong)時準備好(hao)手(shou)套(tao)(tao)和(he)隔(ge)熱(re)(re)盒(he)(he)(he)。2、將(jiang)(jiang)(jiang)爐(lu)溫(wen)(wen)(wen)測(ce)試(shi)儀(yi)(yi)通過數(shu)據(ju)線(xian)(xian)連接(jie)在(zai)電(dian)(dian)腦(nao)上,輕按(an)(an)一(yi)下(xia)測(ce)溫(wen)(wen)(wen)儀(yi)(yi)上的(de)(de)“MODE”鍵,讓“Status"紅(hong)燈慢閃。3、用鼠標左鍵依次單擊(ji)測(ce)試(shi)儀(yi)(yi)的(de)(de)配(pei)套(tao)(tao)應用程序窗(chuang)口(kou)中的(de)(de)“連線(xian)(xian)變(bian)更”和(he)“連線(xian)(xian)申(shen)請(qing)”以清除爐(lu)溫(wen)(wen)(wen)測(ce)試(shi)儀(yi)(yi)中存(cun)儲(chu)的(de)(de)溫(wen)(wen)(wen)度(du)數(shu)據(ju),確定“電(dian)(dian)腦(nao)”窗(chuang)口(kou)中所顯示(shi)的(de)(de)電(dian)(dian)量大(da)于60%。4、斷開測(ce)溫(wen)(wen)(wen)儀(yi)(yi)與電(dian)(dian)腦(nao)的(de)(de)連接(jie),在(zai)回流焊爐(lu)前,將(jiang)(jiang)(jiang)測(ce)溫(wen)(wen)(wen)儀(yi)(yi)放(fang)入隔(ge)熱(re)(re)盒(he)(he)(he),輕按(an)(an)“MODE”按(an)(an)鈕,見“Status”紅(hong)燈快閃時,迅速(su)關上隔(ge)熱(re)(re)盒(he)(he)(he)蓋(gai),并將(jiang)(jiang)(jiang)外置(zhi)PCB和(he)隔(ge)熱(re)(re)蓋(gai)一(yi)同(tong)(tong)放(fang)在(zai)回流焊爐(lu)的(de)(de)鋼網(wang)上,使PCB和(he)隔(ge)熱(re)(re)盒(he)(he)(he)保持至(zhi)少十公分(fen)的(de)(de)距離。5、在(zai)回流焊爐(lu)未端(duan)等(deng)待(dai)PCB及隔(ge)熱(re)(re)盒(he)(he)(he)出爐(lu)后,迅速(su)打(da)開隔(ge)熱(re)(re)盒(he)(he)(he)蓋(gai),輕按(an)(an)一(yi)下(xia)“MODE”鍵,使“Status”紅(hong)燈恢(hui)復慢閃,此時爐(lu)溫(wen)(wen)(wen)儀(yi)(yi)已(yi)停止讀取數(shu)據(ju),且(qie)爐(lu)溫(wen)(wen)(wen)數(shu)據(ju)已(yi)存(cun)入其存(cun)儲(chu)器(qi)中。6、將(jiang)(jiang)(jiang)爐(lu)溫(wen)(wen)(wen)測(ce)試(shi)儀(yi)(yi)中的(de)(de)溫(wen)(wen)(wen)度(du)數(shu)據(ju)下(xia)載到電(dian)(dian)腦(nao)中,分(fen)析溫(wen)(wen)(wen)度(du)曲線(xian)(xian)的(de)(de)合理(li)性,可行則(ze)打(da)印,不行則(ze)及時調整爐(lu)溫(wen)(wen)(wen)。