多功(gong)(gong)能(neng)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)力(li)儀(yi)(yi)表是專為配電(dian)(dian)(dian)(dian)(dian)(dian)(dian)系統、工(gong)礦企(qi)業、公共樓宇的電(dian)(dian)(dian)(dian)(dian)(dian)(dian)力(li)監控系統而設(she)計的電(dian)(dian)(dian)(dian)(dian)(dian)(dian)力(li)設(she)備,它可(ke)以測(ce)量三(san)相(xiang)(xiang)交(jiao)流(liu)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)路上(shang)的常用電(dian)(dian)(dian)(dian)(dian)(dian)(dian)力(li)參數(shu),如三(san)相(xiang)(xiang)相(xiang)(xiang)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)、三(san)相(xiang)(xiang)線電(dian)(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)、三(san)相(xiang)(xiang)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)流(liu)、有功(gong)(gong)、無功(gong)(gong)、視在功(gong)(gong)率(lv)(lv)、功(gong)(gong)率(lv)(lv)因數(shu)、頻率(lv)(lv)、四象(xiang)限電(dian)(dian)(dian)(dian)(dian)(dian)(dian)能(neng)等,使用多功(gong)(gong)能(neng)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)力(li)儀(yi)(yi)表時,需(xu)要(yao)先(xian)將其(qi)安(an)裝好并(bing)接(jie)線,那么(me)多功(gong)(gong)能(neng)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)力(li)儀(yi)(yi)表怎么(me)接(jie)線呢?
一(yi)般來說(shuo),多(duo)功能電力(li)儀表的(de)接(jie)線(xian)方法和接(jie)線(xian)圖在使用(yong)說(shuo)明書(shu)上(shang)都(dou)有,按(an)照接(jie)線(xian)圖將各端子連接(jie)起來即(ji)可,常見的(de)接(jie)線(xian)方法主要有三(san)種:
1、直接接線法
(1)首先確認(ren)電(dian)纜線(xian)的電(dian)壓級別(bie)和(he)電(dian)流(liu)大小(xiao)。將電(dian)纜分(fen)別(bie)連接(jie)到儀表(biao)的L1、L2、L3、N和(he)PE接(jie)線(xian)端(duan)。
(2)將電纜線連接到電源端(duan),確認(ren)線序(xu)正(zheng)確。
(3)確認接線端是否牢固,如有松(song)動需要重新插拔和連(lian)接。
(4)開啟電(dian)源,檢測儀表的電(dian)壓、電(dian)流、功率(lv)等(deng)參數是否符合實際值。
(5)如必要,調整(zheng)儀表(biao)的校準參(can)數,確保(bao)讀數準確。
2、三元組接線法
(1)將(jiang)三根電(dian)纜線(xian)(xian)(A、B、C)依次連接到儀表的L1、L2、L3接線(xian)(xian)端(duan),將(jiang)剩余兩根電(dian)纜線(xian)(xian)(N、PE)連接到儀表的N和(he)PE接線(xian)(xian)端(duan)。
(2)確(que)(que)認連接結果正(zheng)確(que)(que)。
(3)開啟電源,檢測儀表的電壓、電流、功率(lv)等參數(shu)是(shi)否符合實際(ji)值。
(4)如必要,調整儀表的校準參(can)數,確(que)保讀數準確(que)。
3、變壓器接線法
(1)將三根(gen)電(dian)纜(lan)線(A、B、C)分別(bie)接到變(bian)壓器的高壓端,將剩余兩根(gen)電(dian)纜(lan)線(N、PE)接到變(bian)壓器的中性點和接地(di)端。
(2)將變壓器的(de)低(di)壓端(duan)連接到儀表的(de)L1、L2、L3接線端(duan),將剩余兩根電纜線(N、PE)連接到儀表的(de)N和PE接線端(duan)。
(3)確(que)認(ren)連接(jie)結(jie)果正確(que)。
(4)開啟電源,檢測儀表的電壓、電流、功率等參(can)數是(shi)否符合實際值(zhi)。
(5)如(ru)必(bi)要,調整儀表的校準參數,確保讀(du)數準確。
二、三相多功能電力儀表接線注意事項有哪些
三相多功能電力儀表的(de)接(jie)線(xian)(xian)方法多種多樣,可以根據實際情況選(xuan)擇合適(shi)的(de)接(jie)線(xian)(xian)方法,正確(que)的(de)接(jie)線(xian)(xian)方式不(bu)僅可以保證儀(yi)表的(de)正常使用,還(huan)能(neng)有(you)效防止(zhi)安全事故的(de)發生,在進行接(jie)線(xian)(xian)時,還(huan)要(yao)注意以下幾個事項:
1、接(jie)線(xian)(xian)前(qian)需確認電纜(lan)線(xian)(xian)的電壓級別和電流(liu)大小,接(jie)線(xian)(xian)時應保(bao)證線(xian)(xian)序正(zheng)確。
2、接線端應牢(lao)固,如有(you)松動(dong)需要重新插拔和連接。
3、開啟電源前應確認所有接線是否正確,避免短路或(huo)漏電。
4、輸(shu)入電(dian)壓不要高于產品的額定(ding)輸(shu)入電(dian)壓(100V到380V),否(fou)則應(ying)考(kao)慮使用(yong)PT,為了方(fang)便維護,建議使用(yong)接線排。
5、標準額定輸入電流為5A或1A,大于5A的情(qing)況(kuang)應(ying)使(shi)用(yong)(yong)外部CT。如果使(shi)用(yong)(yong)的CT上(shang)連有其他(ta)儀表,接(jie)線應(ying)采用(yong)(yong)串聯方(fang)式,取出產品(pin)的電流輸入連線之前,一定要先(xian)斷開CT一次回(hui)路(lu)或者(zhe)短接(jie)二次回(hui)路(lu),為便于維護建議使(shi)用(yong)(yong)連線排。
6、要確(que)保輸入(ru)電(dian)壓(ya),電(dian)流相對應、相序一(yi)致、方向一(yi)致、否則會出(chu)現功率和(he)電(dian)能等(deng)的數值(zhi)和(he)符合錯(cuo)誤。
7、現場的接線方(fang)式必(bi)須與(yu)表內設置(zhi)的接線方(fang)式一(yi)致,否則(ze)儀表的測量數(shu)據不(bu)正確。