一、電阻壞了有什么現象
電阻是電(dian)(dian)(dian)器設備中(zhong)數(shu)量最多的(de)元件,但不是損(sun)壞(huai)率(lv)最高的(de)元件。電(dian)(dian)(dian)阻(zu)損(sun)壞(huai)以開路最常見(jian),阻(zu)值(zhi)變大較少(shao)見(jian),阻(zu)值(zhi)變小十分少(shao)見(jian)。常見(jian)的(de)有碳膜(mo)電(dian)(dian)(dian)阻(zu)、金屬膜(mo)電(dian)(dian)(dian)阻(zu)、線(xian)繞電(dian)(dian)(dian)阻(zu)和(he)合金電(dian)(dian)(dian)阻(zu)等幾種,在這些(xie)電(dian)(dian)(dian)阻(zu)中(zhong)如何判(pan)斷(duan)它(ta)們在電(dian)(dian)(dian)路中(zhong)是否損(sun)壞(huai),它(ta)們損(sun)壞(huai)后又有哪些(xie)特征(zheng)呢(ni)?
1、線繞電阻損壞的特征
線(xian)繞電阻一般(ban)用作大電流(liu)限流(liu),阻值不(bu)大。
圓柱(zhu)形線繞電阻燒壞時有的會發黑或(huo)表面爆皮、裂紋,有的沒有痕跡。
水泥電阻是線繞電阻的一種,燒(shao)壞時可(ke)能(neng)會(hui)斷(duan)裂,否則也沒有可(ke)見痕跡。
保險(xian)電阻燒壞時有(you)的表面會炸掉一塊(kuai)皮,有(you)的也(ye)沒有(you)什(shen)么痕跡,但(dan)絕(jue)不會燒焦發(fa)黑。
根據以上特點,在檢(jian)查電(dian)阻時(shi)可有所側重(zhong),快速找出(chu)損壞的(de)電(dian)阻。
2、金屬膜電阻和碳膜電阻損壞特征
金屬膜(mo)電阻和(he)碳膜(mo)電阻應用是(shi)(shi)最廣(guang),其損(sun)壞(huai)的特點:一是(shi)(shi)低(di)阻值(100Ω以(yi)下)和(he)高(gao)阻值(100kΩ以(yi)上)的損(sun)壞(huai)率較高(gao),中間阻值(如幾百(bai)歐到幾十千歐)的極少損(sun)壞(huai);二(er)是(shi)(shi)低(di)阻值電阻損(sun)壞(huai)時往往是(shi)(shi)燒(shao)焦(jiao)發(fa)黑(hei),很容(rong)易發(fa)現,而高(gao)阻值電阻損(sun)壞(huai)時很少有痕(hen)跡。
二、怎么測量電阻好壞
1、外觀檢查
對(dui)于固定(ding)電阻(zu)首先查(cha)看標志(zhi)清晰,保護漆完好,無(wu)燒焦,無(wu)傷痕,無(wu)裂痕,無(wu)腐蝕,電阻(zu)體與引腳(jiao)緊(jin)密接觸(chu)等。對(dui)于電位器還應檢(jian)查(cha)轉軸靈活,松緊(jin)適(shi)當,手感舒適(shi)。有開關(guan)的(de)要檢(jian)查(cha)開關(guan)動作是否正常。
2、萬用表檢測
①固定電阻的檢測
用萬用表(biao)的(de)電(dian)阻(zu)擋(dang)對電(dian)阻(zu)進行測量,對于測量不同阻(zu)值的(de)電(dian)阻(zu)選擇萬用表(biao)的(de)不同倍乘擋(dang)。對于指針式(shi)萬用表(biao),由于電(dian)阻(zu)擋(dang)的(de)示(shi)數是非線性的(de),阻(zu)值越(yue)大,示(shi)數越(yue)密,所以選擇合適的(de)量程,應使表(biao)針偏轉角大些,指示(shi)于1/3~2/3滿量程,讀數更為(wei)準確。若測得阻(zu)值超過(guo)該電(dian)阻(zu)的(de)誤差范圍、阻(zu)值無限大、阻(zu)值為(wei)0或阻(zu)值不穩,說明該電(dian)阻(zu)器(qi)已壞。
在(zai)測(ce)量中注意拿電(dian)(dian)(dian)阻(zu)的(de)(de)手(shou)不要與(yu)電(dian)(dian)(dian)阻(zu)器的(de)(de)兩個引腳相接觸(chu),這(zhe)樣會使手(shou)所呈現的(de)(de)電(dian)(dian)(dian)阻(zu)與(yu)被測(ce)電(dian)(dian)(dian)阻(zu)并聯,影響測(ce)量準確。另外(wai),不能帶電(dian)(dian)(dian)情(qing)況下(xia)用萬用表電(dian)(dian)(dian)阻(zu)擋檢測(ce)電(dian)(dian)(dian)路中電(dian)(dian)(dian)阻(zu)器的(de)(de)阻(zu)值。在(zai)線檢測(ce)應首先斷電(dian)(dian)(dian),再將電(dian)(dian)(dian)阻(zu)從電(dian)(dian)(dian)路中斷開(kai)出來,然(ran)后進行測(ce)量。
②保險絲電阻和敏感電阻的檢測
保(bao)險絲(si)電(dian)(dian)阻(zu)一(yi)般阻(zu)值(zhi)(zhi)只有幾到幾十(shi)歐,若測(ce)(ce)得阻(zu)值(zhi)(zhi)為無限大,則(ze)已熔(rong)斷。也可在線檢測(ce)(ce)保(bao)險絲(si)電(dian)(dian)阻(zu)的好壞,分別測(ce)(ce)量其兩端(duan)對地電(dian)(dian)壓,若一(yi)端(duan)為電(dian)(dian)源電(dian)(dian)壓,一(yi)端(duan)電(dian)(dian)壓為0伏,保(bao)險絲(si)電(dian)(dian)阻(zu)已熔(rong)斷。
敏感電(dian)(dian)(dian)阻種類(lei)較多,以熱(re)敏電(dian)(dian)(dian)阻為例,又(you)分正(zheng)(zheng)溫(wen)(wen)度(du)系數和負(fu)溫(wen)(wen)度(du)系數熱(re)敏電(dian)(dian)(dian)阻。對于(yu)正(zheng)(zheng)溫(wen)(wen)度(du)系(PTC)熱(re)敏電(dian)(dian)(dian)阻,在常(chang)溫(wen)(wen)下(xia)一(yi)般阻值(zhi)不大,在測(ce)量中用燒熱(re)的電(dian)(dian)(dian)烙鐵靠近電(dian)(dian)(dian)阻,這時阻值(zhi)應明顯增大,說(shuo)明該電(dian)(dian)(dian)阻正(zheng)(zheng)常(chang),若(ruo)無變化說(shuo)明元件損壞,負(fu)溫(wen)(wen)度(du)系熱(re)敏電(dian)(dian)(dian)阻則(ze)相(xiang)反。
光敏(min)電阻(zu)在無光照(用手或(huo)物(wu)遮(zhe)住光)的情況下萬(wan)用表測得(de)阻(zu)值大,有光照表針指(zhi)示電阻(zu)值有明顯減小。若無變(bian)化,則元件損壞(huai)。
③可變電阻和電位器的檢測
首先測(ce)量(liang)兩固定(ding)端之間電阻(zu)值(zhi)是(shi)否正常,若為無限大或為零歐(ou),或與(yu)標稱相(xiang)差(cha)較(jiao)大,超過(guo)誤差(cha)允許范圍,都說明已損(sun)壞(huai);電阻(zu)體阻(zu)值(zhi)正常,再將(jiang)萬用表一(yi)(yi)只表筆(bi)接電位器滑動(dong)端,另一(yi)(yi)只表筆(bi)接電位器(可調電阻(zu))的(de)任一(yi)(yi)固定(ding)端,緩慢旋動(dong)軸柄,觀察表針是(shi)否平(ping)穩變(bian)化(hua)(hua),當從一(yi)(yi)端旋向另一(yi)(yi)端時,阻(zu)值(zhi)從零歐(ou)變(bian)化(hua)(hua)到標稱值(zhi)(或相(xiang)反),并(bing)且無跳變(bian)或抖動(dong)等現(xian)(xian)象,則說明電位器正常,若在(zai)旋轉的(de)過(guo)程中(zhong)有跳變(bian)或抖動(dong)現(xian)(xian)象,說明滑動(dong)點現(xian)(xian)電阻(zu)體接觸不良。
3、用電橋測量電阻
如果要求精確測量電阻器的(de)阻(zu)(zu)(zu)(zu)值(zhi),可通過電橋(數字式)進行測試(shi)。將電阻(zu)(zu)(zu)(zu)插入電橋元件測量端,選擇合適的(de)量程,即可從(cong)顯示器(qi)上讀出電阻(zu)(zu)(zu)(zu)器(qi)的(de)阻(zu)(zu)(zu)(zu)值(zhi)。例如,用電阻(zu)(zu)(zu)(zu)絲自制電阻(zu)(zu)(zu)(zu)或(huo)對固(gu)定(ding)電阻(zu)(zu)(zu)(zu)器(qi)進行處理來獲得某一較為(wei)精(jing)確的(de)電阻(zu)(zu)(zu)(zu)值(zhi)時,就必須用電橋測量自制電阻(zu)(zu)(zu)(zu)的(de)阻(zu)(zu)(zu)(zu)值(zhi)。