co2激光切割機在運行切割過程中突然不出光
1、激(ji)光(guang)(guang)管(guan)是否出(chu)光(guang)(guang),出(chu)光(guang)(guang),則運(yun)動(dong)(dong)控制(zhi)卡上面的線松,或動(dong)(dong)運(yun)動(dong)(dong)控制(zhi)卡壞(更換板(ban)卡)。不出(chu)光(guang)(guang),激(ji)光(guang)(guang)電源(yuan)(yuan)壞。(極(ji)少情況(kuang)激(ji)光(guang)(guang)管(guan)壞) (檢查(cha)激(ji)光(guang)(guang)管(guan)高壓(ya)端是否有(you)打火(huo)現象,打火(huo)容(rong)易(yi)把(ba)激(ji)光(guang)(guang)電源(yuan)(yuan)和板(ban)卡的電子元件燒掉)。
?激(ji)光電(dian)源(yuan)(yuan)風扇(shan)不(bu)轉,用電(dian)筆測試激(ji)光電(dian)源(yuan)(yuan)220V端(duan)口,是否有電(dian)。有電(dian),激(ji)光電(dian)源(yuan)(yuan)壞。(維修或更換電(dian)源(yuan)(yuan));沒電(dian),檢(jian)查(cha)激(ji)光電(dian)源(yuan)(yuan)開關,線路。
2、開機不出光,操作員不是很熟悉機器操作流程。
3、 檢(jian)查水箱是否報警
3.1 不(bu)報警,檢(jian)查激光(guang)電(dian)(dian)源風(feng)扇(shan)是否(fou)在(zai)轉。 激光(guang)電(dian)(dian)源風(feng)扇(shan)轉,用電(dian)(dian)線短接激光(guang)電(dian)(dian)源的。
3.2 報警(jing),把水(shui)(shui)(shui)箱(xiang)后面的(de)進水(shui)(shui)(shui)口(kou),出水(shui)(shui)(shui)口(kou)用一(yi)條水(shui)(shui)(shui)管連(lian)接,水(shui)(shui)(shui)箱(xiang)通(tong)電,看(kan)是否報警(jing)。如果報警(jing),水(shui)(shui)(shui)箱(xiang)壞(huai)了。如果不警(jing),則是激光管水(shui)(shui)(shui)路(lu)不暢通(tong),檢查水(shui)(shui)(shui)管是否折彎或被(bei)東西壓(ya)住,水(shui)(shui)(shui)箱(xiang)里的(de)水(shui)(shui)(shui)是否有雜(za)物(更換水(shui)(shui)(shui)箱(xiang)的(de)純凈(jing)水(shui)(shui)(shui))。
要檢查以下幾個方面
1、光路是否正常。(按出光看激(ji)光管是否亮,亮而激(ji)光頭(tou)沒(mei)光,則(ze)光路有問題)
2、激光電源開(kai)關(guan)是否(fou)打開(kai)。
3、水(shui)箱(xiang)是否打開。
4、機(ji)器操作面(mian)板(ban),功率是(shi)否(fou)正確。或電(dian)腦軟件參(can)數是(shi)否(fou)正確。