一、吊扇一般用多大的電容
吊扇的電容看電機大小而定的,有1微法的,也有2微法的,一般用2微法的多,吊扇的啟動(dong)電容(rong)一般(ban)2~2.5uF。
一(yi)般電(dian)動(dong)機功率(lv)65-100W,匹配2~4uf電(dian)容耐(nai)壓最好在650V,建議80W吊(diao)扇用3uF/400v的(de)啟動(dong)電(dian)容,1.2至1.5uF的(de)電(dian)容用于30W至60W的(de)電(dian)扇還行。
單相吊(diao)扇(shan)(shan)多為電(dian)(dian)(dian)(dian)容運轉電(dian)(dian)(dian)(dian)機,電(dian)(dian)(dian)(dian)容從風(feng)扇(shan)(shan)啟(qi)動開始(shi)就(jiu)一(yi)直參與運行,即按規(gui)律充放(fang)電(dian)(dian)(dian)(dian),電(dian)(dian)(dian)(dian)容容量越(yue)大(da),充放(fang)電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)流就(jiu)越(yue)大(da),產生的電(dian)(dian)(dian)(dian)磁(ci)能就(jiu)越(yue)大(da),風(feng)扇(shan)(shan)轉速(su)就(jiu)越(yue)快,此時(shi)風(feng)扇(shan)(shan)轉速(su)會高于(yu)正常轉速(su),風(feng)扇(shan)(shan)磨損就(jiu)越(yue)大(da),發熱也(ye)越(yue)大(da),壽命就(jiu)越(yue)短,而耗電(dian)(dian)(dian)(dian)量并非會增(zeng)大(da)。
二、吊扇電容接線方法
總原則:火線經吊扇調速開關,接入(ru)(ru)機頭;零線(xian)直接接入(ru)(ru)機頭。
步驟:
1、受調速器(qi)控制(zhi)的火(huo)線,與零線,最好穿(chuan)(chuan)過(guo)吊桿,主要是為了美觀。可以直接穿(chuan)(chuan)。
2、如(ru)果不(bu)好(hao)穿(chuan),可以把(ba)兩根電線(xian)(xian)的(de)頭部(bu)絞(jiao)起來,再(zai)慢慢傳。還不(bu)好(hao)穿(chuan),則可以另外找來一根線(xian)(xian),一端與兩根線(xian)(xian)綁好(hao)。
3、線的另(ling)一端穿過吊桿,線到(dao)達下面,使勁(jing)拉(la)扯,直到(dao)電線出來。
4、機(ji)頭出廠的(de)接法,不要動。特(te)別是圓圈中的(de)線頭,不可拆(chai)開。
5、標有L字(zi)母的,接(jie)火線(xian);標有N字(zi)母的,接(jie)零(ling)線(xian),G10L接(jie)火線(xian),N接(jie)零(ling)線(xian)。
6、正常情況下(xia),零線接上面(mian)(mian)的(de)(de)孔(kong)(kong),火線接下(xia)面(mian)(mian)的(de)(de)孔(kong)(kong)。