通(tong)常用(yong)(yong)普(pu)通(tong)電(dian)流(liu)(liu)表(biao)測(ce)量電(dian)流(liu)(liu)時,需要將電(dian)路切斷(duan)停機(ji)后才能將電(dian)流(liu)(liu)表(biao)接入(ru)進行測(ce)量,這(zhe)是很(hen)麻煩的,有時正(zheng)常運(yun)行的電(dian)動(dong)機(ji)不(bu)允(yun)許這(zhe)樣做。此(ci)時,使用(yong)(yong)鉗形電(dian)流(liu)(liu)表(biao)就顯得方便多了,可以在不(bu)切斷(duan)電(dian)路的情況(kuang)下來測(ce)量電(dian)流(liu)(liu)。
穿(chuan)過(guo)(guo)鐵心的(de)被測電(dian)路導線(xian)就成為(wei)電(dian)流(liu)(liu)互感器的(de)一(yi)次(ci)線(xian)圈(quan),其中通(tong)過(guo)(guo)電(dian)流(liu)(liu)便(bian)(bian)在二次(ci)線(xian)圈(quan)中感應出(chu)電(dian)流(liu)(liu)。從(cong)而使(shi)二次(ci)線(xian)圈(quan)相連接的(de)電(dian)流(liu)(liu)表便(bian)(bian)有(you)指示-----測出(chu)被測線(xian)路的(de)電(dian)流(liu)(liu)。鉗形表可(ke)以通(tong)過(guo)(guo)轉換開(kai)關的(de)撥(bo)檔,改換不同(tong)的(de)量程。但(dan)撥(bo)檔時不允(yun)許帶電(dian)進行操(cao)作。鉗形表一(yi)般(ban)準確(que)度不高,通(tong)常為(wei)2.5~5級。為(wei)了使(shi)用方便(bian)(bian),表內還有(you)不同(tong)量程的(de)轉換開(kai)關供測不同(tong)等級電(dian)流(liu)(liu)以及測量電(dian)壓(ya)的(de)功能。
小巧輕便的鉗(qian)形表。
40A/400AAC/DC
400V/600VAC,DC
電(dian)阻(zu)/蜂鳴功能(neng)。
自動關機功能。
數據保持功能。
最大顯(xian)示4000計數。
自動回零功能。
設計符合國(guo)際安全(quan)規格IEC61010-1CAT.III300V
用(yong)鉗(qian)(qian)形(xing)電(dian)(dian)流(liu)(liu)表(biao)檢(jian)(jian)(jian)測電(dian)(dian)流(liu)(liu)時,一(yi)定要夾入一(yi)根被測導(dao)線(xian)(電(dian)(dian)線(xian)).夾入兩根(平行線(xian))則(ze)(ze)不能檢(jian)(jian)(jian)測電(dian)(dian)流(liu)(liu).另(ling)外,使用(yong)鉗(qian)(qian)形(xing)電(dian)(dian)流(liu)(liu)表(biao)中(zhong)心(鐵心)檢(jian)(jian)(jian)測時,檢(jian)(jian)(jian)測誤差小.在檢(jian)(jian)(jian)查家電(dian)(dian)產品的(de)耗電(dian)(dian)量時,使用(yong)線(xian)路(lu)分離器比較方便,有的(de)線(xian)路(lu)分離器可(ke)將(jiang)檢(jian)(jian)(jian)測電(dian)(dian)流(liu)(liu)放大10倍,因此1A以下的(de)電(dian)(dian)流(liu)(liu)可(ke)放大后再檢(jian)(jian)(jian)測.用(yong)直流(liu)(liu)鉗(qian)(qian)形(xing)電(dian)(dian)流(liu)(liu)表(biao)檢(jian)(jian)(jian)測直流(liu)(liu)電(dian)(dian)流(liu)(liu)(DCA)時,如果電(dian)(dian)流(liu)(liu)的(de)流(liu)(liu)向相反,則(ze)(ze)顯示出負數.可(ke)使用(yong)該功能檢(jian)(jian)(jian)測汽車的(de)蓄電(dian)(dian)池是(shi)充電(dian)(dian)狀(zhuang)態還是(shi)放電(dian)(dian)狀(zhuang)態.
平(ping)均值方式的(de)鉗形電流(liu)表通過(guo)交流(liu)檢測(ce),檢測(ce)正弦(xian)波(bo)(bo)(bo)的(de)平(ping)均值,并將放大1.11倍(bei)(正弦(xian)波(bo)(bo)(bo)交流(liu))之后(hou)的(de)值作為有(you)效值顯示出(chu)來.波(bo)(bo)(bo)形率(lv)不同的(de)正弦(xian)波(bo)(bo)(bo)以外的(de)波(bo)(bo)(bo)形和歪波(bo)(bo)(bo)也同樣放大1.11倍(bei)后(hou)顯示出(chu)來,所以會產生(sheng)指示誤差.因此檢測(ce)正弦(xian)波(bo)(bo)(bo)以外的(de)波(bo)(bo)(bo)形和歪波(bo)(bo)(bo)時(shi),請選用可直接測(ce)試出(chu)真有(you)效值的(de)鉗形電流(liu)表.
漏(lou)電(dian)(dian)(dian)(dian)檢測(ce)與(yu)通(tong)常的(de)(de)(de)電(dian)(dian)(dian)(dian)流檢測(ce)不(bu)同,兩根(單(dan)相(xiang)2線(xian)式)或三(san)根(單(dan)相(xiang)3線(xian)式,三(san)相(xiang)3線(xian)式)要(yao)全(quan)部夾(jia)住。也可夾(jia)住接地線(xian)進(jin)行檢測(ce).在低壓電(dian)(dian)(dian)(dian)路上檢測(ce)漏(lou)電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)流的(de)(de)(de)絕緣管理方法,已(yi)成(cheng)為首要(yao)的(de)(de)(de)判斷手(shou)段.自(zi)其被(1997年電(dian)(dian)(dian)(dian)氣設備(bei)技術標準的(de)(de)(de)修正)確認以來,在不(bu)能停(ting)電(dian)(dian)(dian)(dian)的(de)(de)(de)樓宇和工廠,便逐漸采用漏(lou)電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)流鉗表來檢測(ce).
①進行電流(liu)測量時(shi),被測載流(liu)體的位置應(ying)放在鉗口(kou)中央,以免產生誤差。
②測(ce)量(liang)(liang)前應估計(ji)被測(ce)電(dian)(dian)流(liu)的(de)大小,選擇(ze)合適的(de)量(liang)(liang)程,在(zai)不知道電(dian)(dian)流(liu)大小時(shi),應選擇(ze)最大量(liang)(liang)程,再根據指(zhi)針適當減小量(liang)(liang)程,但不能在(zai)測(ce)量(liang)(liang)時(shi)轉換(huan)量(liang)(liang)程。
③為了(le)使讀數準確,應保持(chi)鉗口(kou)干凈無損,如有污垢時(shi),應用汽油擦(ca)洗干凈再進(jin)行測量(liang)。
④在測量5A以下的電流時(shi),為了(le)測量準確(que),應(ying)該繞(rao)圈測量。
⑤鉗形表不能測量裸導線電流,以防(fang)觸電和(he)短路。
⑥測量完(wan)后一定要(yao)將量程分檔旋鈕放到最大(da)量程位(wei)置上。